Mineral Insulated Cables

Mineral Insulated Cables

MOQ : 1 Piece

Business Type Manufacturer, Exporter, Supplier
Country of Origin India
Thickness 9.5-10mm
Certification ISO 9001:2008
Click to view more

Preferred Buyer From

Location Worldwide

Product Details

Length
5-10mtr
Feature
Quality Assured, High Tensile Strength, High Ductility, Crack Free

A mineral insulated cable (MI cable), a specialised kind of cable used in high temperatures or harsh environmental conditions, has a low flammability even when running at high temperatures. It can withstand oxidation and allows for accurate measuring.

When utilised in chemically active or moist situations, the metal sheath that covers MI cable aids in preventing the thermocouple wires from oxidation. Mineral insulated cable is the best choice for usage in locations where failure and repair could be risky or even impossible due to corrosion. For instance, nuclear power reactors utilise MI wire to track core temperatures.

The thermocouple wires are kept from coming into touch with other thermocouple wires or with caustic materials like oils, solvents, or water by the superior non- reactive insulation provided by the mineral fillers of MI cables. In applications like heat treatment or sintering, where the quality of the product could be severely affected by temperature variations, this helps to ensure that the thermocouple probes remain correct.

Yes! I am interested


Specification

Sheath Size(mm) Conductor Diameter(mm)
Diameter Wall Thickness K N E J T S R B
0.25 0.025-0.035 0.04-0.05 -
0.5 0.05-0.1 0.08-0.12 -
1 0.1-0.2 0.15-0.2 -
1.5 0.15-0.25 0.23-0.3 0.15-0.2
2 0.2-0.35 0.3-0.5 0.2-0.25
3 0.3-0.45 0.45-0.6 0.3-0.35
4 0.4-0.6 0.55-0.7 0.4-0.45
4.5 0.45-0.6 0.68-0.8 0.4-0.45
5 0.5-0.8 0.7-0.9 0.45-0.5
6 0.6-0.9 0.9-1.1 0.45-0.5
8 0.8-1.2 1.2-1.4 -
3 0.3-0.45 0.45-0.6 0.3-0.35
4 0.4-0.6 0.55-0.7 0.4-0.45
4.5 0.45-0.65 0.68-0.8 0.4-0.45
5 0.5-0.8 0.7-0.9 0.45-0.5
6 0.6-0.9 0.9-1.1 0.45-0.5
8 0.8-1.2 1.2-1.4 -

Specification 01

Type Code Graduation Sheath Material Outer dia. (mm) Temperature Range
Ni Cr - Ni Si KK K SS304 0.5-1.0 400
SS321 1.5 - 3.2 600
SS316 4.0 - 8.0 800
0.5 - 1.0 500
SS310 1.5 - 3.2 800
INCL600 4.0 - 6.4 900
8.0 - 12.7 1000
Ni Cr Si - Ni Si NK N SS304 0.5-1.0 400
SS321 1.5 - 3.2 600
SS316 4.0 - 8.0 800
0.5 - 1.0 500
SS310 1.5 - 3.2 800
INCL600 4.0 - 6.4 900
8.0 - 12.7 1000
Ni Cr - Konstantan EK E SS304 0.5-1.0 400
SS321 1.5-3.2 500
SS316 4.0 - 8.0 800
Fe - Konstantan JK J SS304 1 300
SS321 1.5-3.2 500
SS316 4.0 - 8.0 800
Cu - Konstantan TK T SS304 1 -300
SS321 1.5-3.2 100-200